The standard temperature ±2˚C during the automatic operation. Error due to mismatching capacity of indoor and outdoor unit. E-217: hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch on the port is set to Off, E-218: When there’s at least one or more actual number of indoor unit connection compared to number of indoor units assigned to MCU, E-219: Error on temperature sensor located on MCU intercooler inlet, E-220: Error on temperature sensor located on MCU intercooler outlet, E-221: Error on outdoor temperature sensor of outdoor unit, E-231: Error on COND OUT temperature sensor of main outdoor unit, E-251: Error on discharge temperature sensor of compressor 1, E-257: Error on discharge temperature sensor of compressor 2, E-262: Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe, E-263: Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe, E-266: Top sensor of compressor 1 is detached, E-267: Top sensor of compressor 2 is detached, E-269: Suction temperature sensor is detached from the sensor holder on the pipe, E-276: Error on top sensor of compressor 1 (Short or Open), E-277: Error on top sensor of compressor 2 (Short or Open), E-291: Refrigerant leakage or error on high pressure sensor (Short or Open), E-296: Refrigerant leakage or error on low pressure sensor (Short or Open), E-308: Error on suction temperature sensor (Short or Open), E-311: Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or Open), E-321: Error on EVI (ESC) IN temperature sensor (Short or Open), E-322: Error on EVI (ESC) OUT temperature sensor (Short or Open), E-323: Error on suction sensor 2 (Short or Open), E-346: Error due to operation failure of Fan2, E-347: Motor wire of Fan2 is not connected, E-348: Lock error on Fan2 of outdoor unit, E-353: Error due to overheated motor of outdoor unit’s Fan2, E-355: Error due to overheated IPM of Fan2, E-361: Error due to operation failure of inverter compressor 2, E-364: Error due to over-current of inverter compressor 2, E-365: V-limit error of inverter compressor 2, E-366: Error due to over voltage /low voltage of inverter PBA2, E-367: Error due to unconnected wire of compressor 2, E-368: Output current sensor error of inverter PBA2, E-369: DC voltage sensor error of inverter PBA2, E-374: Heat sink temperature sensor error of inverter PBA2, E-385: Error due to input current of inverter 2, E-386: Over-voltage/low-voltage error of Fan2, E-389: V-limit error on Fan2 of compressor, E-393: Output current sensor error of Fan2, E-399: Heat sink temperature sensor error of Fan2, E-400: Error due to overheat caused by contact failure on IPM of Inverter PBA2, E-407: Compressor operation stop due to high pressure protection control, E-410: Compressor operation stop due to low pressure protection control or refrigerant leakage, E-416: Compressor operation stop due to discharge temperature protection control, E-425: Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase input, E-428: Compressor operation stop due abnormal compression ratio, E-438: EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI, E-440: Heating mode restriction due to high air temperature, E-441: Cooling mode restriction due to low air temperature, E-442: Refrigerant charing restriction in heating mode when air temperature is over 15 °C, E-443: Operation prohibited due to low pressure, E-446: Error due to operation failure of Fan1, E-447: Motor wire of Fan1 is not connected, E-452: Error due to ZPC detection circuit problem or power failure, E-453: Error due to overheated motor of outdoor unit’s Fan1, E-455: Error due to overheated IPM of Fan1, E-461: Error due to operation failure of inverter compressor 1, E-462: Compressor stop due to full current control or error due to low current on CT2, E-464: Error due to over-current of inverter compressor 1, E-465: V-limit error of inverter compressor 1, E-466: Error due to over voltage /low voltage of inveter PBA1, E-467: Error due to unconnected wire of compressor 1, E-468: Output current sensor error of inverter PBA1, E-469: DC voltage sensor error of inver PBA1, E-474: Heat sink temperature sensor error of inverter PBA1, E-485: Error due to input current of inverter 1, E-486: Error due to over voltage/low voltage of Fan, E-489: V-limit error on Fan1 of compressor, E-493: Output current sensor error of Fan1, E-499: Heat sink temperature sensor error of Fan1, E-500: Error due to overheat caused by contact failure on IPM of Inverter PBA1, E-503: Error due to alert the user to check if the service valve is closed, E-504: Error due to self diagnosis of compressor operation, E-505: Error due to self diagnosis of high pressure sensor, E-506: Error due to self diagnosis of low pressure sensor, E-560: Outdoor unit’s option switch setting error (when iinappropriate option switch is on), E-563: Error due to module installation of indoor unit with old version (Micom version needs to be checked), E-573: Error due to using single type outdoor unit in a module installation, E-601: Communication error between remote controller and the DVM Hydro unit / Hydro unit HT, E-602: Communication error between master and slave remote controller, E-604: Tracking error between remote controller and the DVM Hydro unit / Hydro unit HT, E-618: Error due to exceeding maximum numbers of Hydro unit installation (16 units), E-627: Error due to exceeding maximum numbers of wired remote controller installation (2 units), E-628: DMS↔Transmitter Communication Error, E-630: ERV wire remote controller normal ventilation option set error, E-631: ERVWire Remote controller auto ventilation option set error, E-632: Error when input the pulse except set the value of Pulse Width by PIM, E-633: Error caused by installing mixed models, E-652: Two wired remote controllers have been set to Master mode (COM1 wiring), E-653: Remote controller’s temperature sensor is disconnected or has problem, E-654: Data error on remote controller (Memory read/write error), E-701: Floating switch error on the indoor unit (1st detection), E-702: Error due to closed EEV of indoor unit (1st detection), E-703: Error due to opened EEV of indoor unit (1st detection), E-901: Error on the sensor of water inlet pipe (Short or Open), E-902: Error on the sensor of water outlet pipe (Short or Open), E-904: Error on water tank (Short or open), E-907: Error due to pipe rupture protection, E-908: Error due to freeze prevention (Re-operation is possible), E-909: Error due to freeze prevention (Re-operation is impossible), E-910: Water temperature sensor on water outlet pipe is detached, E-911: Flow switch off error, When the switch is turned off within 10 seconds after a pump starts its operation (Re-operation is possible), E-913: Six times detection for Flow Switch Error (Re-operation is not possible), E-914: Error due to incorrect thermostat connection, E-917: Water Tank Sensor Configutation Error, UP: Trial operation incompleted (UnPrepared) – It will be cleared when trial operation was executed for 1 hour or when automatic inspection is completed. E-102: Communication error between indoor unit and outdoor unit. No communication for 2 minutes between indoor and outdoor unit (communication error for more than 2minutes). Check input power. Error on discharge temperature sensor of compressor 1 (Short or Open). Check sensor resistance. Odors permeate in the room during operation. any ideas what i have to check? If may not be a fire but it can be a steam generated by the defrost operation from outdoor heat exchanger during Heat mode in winter. Samsung Split System Air Conditioning Outdoor Unit Diagram . That has been 3 months ago. We also use third-party cookies that help us analyze and understand how you use this website. Clean them frequently. Emission temperature excessively high. Check on repeated indoor unit main address. High pressure blockage error (Refrigerant completely Leakage error). Error code related to the Communications / Settings / HW (cont. Check that Com1, Com2 setting DIP switch isset to Com2. Check for leaksfrom the connection part of the pipe and product or from the pipe joint. Ho da poco acquistato il condizionatore modello AJ050NCJ2EG.. Dopo pochi minuti dall'installazione l'unità interna ha dato errore E559 (ho letto altre discussioni su altri modelli con lo stesso errore e mi pare di capire che si tratti di un errore dell'unità esterna). Indoor unit Room Thermistor Open/Short. Check electrical connection and setting, Outdoor communication error between main micom and inverter micom, Outdoor communication error beween main micom and hub micom, Outside temperature sensor error(Short/Open) - Error level: over 4.9V(-50°C) under 0.4V(93°C), Condenser temperature sensor error(Short/Open) - Error level: over 4.9V(-50°C) under 0.4V(93°C), Outdoor unit sensor error - Condenser out sensor(Short/Open) - Self diagnosis, Compressor Discharge temperature sensor error, Compressor discharge sensor detached - Self diagnosis, Compressor OLP sensor error (Short/Open) - Error condition : outdoor temperature under -20°C - Error level : over 4.95V(-30°C) under 0.5V(151°C), Outdoor unit freezing(Compressor stop). For additional questions regarding Samsung Premium Care, please call 1-866-371-9501. Error on current sensor (Short or Open). But opting out of some of these cookies may affect your browsing experience. I have a problem in Samsung inverter split a.c unit.indoor unit show error E109.What its means and what should I do.please help. and the list goes on and on and on they even promised to replace it but that never eventuated…, its e203 communication error…lose or bad wire between indoor and outdoor unit. Buonasera, mi sono appena iscritta sperando di poter trovare una soluzione al mio problema. Check sensor location. Check electrical connection and setting between indoor unit MAIN PBA - INVERTER PBA. Function 1 CN22 download (PC) (SMW200-10 black) 6 Set up the number of connected outdoor units 2 MICOM. Wenn auf Ihrem Samsung AC Fehlercodes angezeigt werden, werden Sie auf ein Problem aufmerksam gemacht. Pressthe Temp + or - button on the remote controller to change the set temperature. E-216: When indoor unit is not installed to a MCU port but the switch on the port is set to On. Your email address will not be published. Check pipe lenght, refrigerant leakage/charge, Outdoor unit high discharge temperature - Safety control (Compressor stop). Is the selected temperature too high? Protection of Outdoor Overload (when Comp. Samsung Air Conditioning Fault Codes: Full list of the Samsung range of air conditioning units. Check if the air conditioner is operating in De-ice mode.When the ice formed in winter or the outdoor temperature is too low, the air conditioner operates in De-ice mode automatically. Check the operation of the EEV. Nel video vengono illustrati i veri step su come configurare l'indirizzamento dei vari split Samsung installati nel vostro impianto. Please share your ZIP Code to find a nearby Best Buy location Refer to the following chart if the air conditioner operates abnormally. [Inverter] OTP error. Die Fehlercode-Definition zu kennen, wird Ihnen helfen… Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. E-108: Error due to repeated address setting, E-121: Error on indoor temperature sensor of indoor unit, E-122: Error on EVA IN sensor of indoor unit, E-123: Error on EVA OUT sensor of indoor unit, E-128: EVA IN temperature sensor of indoor unit is detached from EVA IN pipe, E-129: EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe, E-130: Heat exchanger in/out sensors of indoor unit are detached, E-135: RPM feedback error of indoor unit’s cleaning fan. [Inverter] Emission temperature sensor error. Is the selected temperature too low? Check that wired remote controller is connected to the COM2 terminal of the indoor unit. Check the compressor connection status. Make sure nothing is blocking your remote controllersensor. Related Questions If the indicator is still blinking, contact the service center. Check EEPROM DATA. Check Discharge sensor Open / Short. Check AC Power and DC Link Voltage. Samsung pays for Premium Care during this period. hitachi air conditioner repair center in hyderabad hitachi air conditioner repair center in hyderabad Whatever the problem might be,don’t worry we have very good technicians who can handle and give a solution to the problem. Take the cover off and take the obstacle away. Check the input power. That next week never comes. Error due to duplicated communication address. Ciao Carlo_96 e benvenuto. Error of the condensor temperature sensor. Pressthe Power button or disconnect the power plug/switch off the auxiliary power switch. najim July 19, 2020. one time my NIKAI split ac came E5, then I called technician. Check sensor connection status. Salve a tutti, mi chiamo Carlo e ormai da due anni/estati, in modo alternante, mi compare su una delle due unità interne il codice di errore E5 59. Prezzo per lavori di assistenza condizionatore samsung a milano Calcola il prezzo gratis ONLINE In un minuto e senza impegno Check whether the outdoor unitservice valve is open. The error indicated on the LED display of Indoor unit; Outdoor Unit Error mode and check method; Explanation: Communication error (indoor unable to receive data), Main checking Point: Communication cable connection, Explanation: Communication error (outdoor unable to communicate), Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Explanation: Indoor unit sensor error – Evaporator pipe in sensor detached, Explanation: Indoor unit sensor error – Evaporator pipe out sensor detached, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point: Indoor unit operation mode, Explanation: The number of indoor unit mismatched, Main checking Point: Communication wiring, Explanation: Communication error (outdoor unable to receive data), Explanation: Communication error between 2 microcontroller on the outdoor PCB, Explanation: Condenser temperature sensor error (Short/Open), Explanation: Condenser temperature sensor detached, Explanation: Compressor discharge sensor error (Short/Open), Explanation: Compressor discharge sensor detached, Explanation: Compressor OLP sensor error (Short/Open), Explanation: Indoor unit heat exchanger freezing and compressor stop (cooling mode), Main checking Point: Check pipe matching also (indoor-outdoor), Explanation: Outdoor unit overload and compressor stop (protection control in heating mode), Explanation: Outdoor unit high discharge temperature and compressor stop, Main checking Point: Check pipe matching (indoor-outdoor), Explanation: Outdoor unit EEV open error (self diagnosis), Explanation: Outdoor unit EEV close error (self diagnosis), Explanation: High temperature (over 30˚C) of outdoor as heating mode, Explanation: Low temperature (under -5˚C) of indoor as cooling mode, Explanation: Wrong connection between communication and power cable, Main checking Point: Wiring indoor and outdoor, Explanation: Inverter Compressor starting failure (5 times), Main checking Point: Service valve, EEV, Compressor terminal, Compressor wire, Outdoor controller, Explanation: Compressor trip by input current limit control, Main checking Point: EEV, Gas over charge, Outdoor controller, Explanation: Compressor trip by OLP temperature limit control, Main checking Point: Outdoor fan, Compressor,  Outdoor controller, Explanation:  Compressor peak current protection, Main checking Point:  Outdoor fan, Compressor, Compressor wire, Outdoor controller, Explanation: Compressor overload protection by current, Main checking Point: Outdoor fan, EEV, Service valve, Outdoor controller, Explanation: DC-link voltage error (under 150V or over 410V), Main checking Point: Power voltage, Outdoor controller, Main checking Point: Compressor terminal, Compressor wire, Outdoor controller, Explanation:  DC-link voltage sensor error, Explanation: Compressor overload protection, Main checking Point: Outdoor fan, EEV, Service valve, Outdoor controller, Explanation: AC line zero-crossing detection circuit error, Main checking Point: Outdoor controller, Terminal Block, Explanation: NO GAS error (self diagnosis), Samsung VRF (DVM S) System AC Error Codes. It’s a normal thing, because you deal with the technological stuff made by human. Check the connection wire between the indoor unit and the wired remote controller. Samsung Split Type, Multi System and VRF System AC Error Codes and Troubleshooting; Outdoor LED Display Error and Check Method (12K/18K/24K)-Samsung Split System Air Conditioning Outdoor LED Light Errors, Explanation: Communication error (unable to receive data), Main checking Point/Remark: Communication cable connection, Explanation: Communication error (outdoor cannot communicate), Main checking Point/Remark: Another indoor unit or indoor PCB, Explanation: Indoor unit room temperature sensor error (Open/Short), Main checking Point/Remark: Room temperature sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger in sensor, indoor PCB, Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger out sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor detached, Main checking Point/Remark: Heat exchanger in sensor, Explanation: Indoor unit heat exchanger out temperature sensor detached, Main checking Point/Remark: Heat exchanger out sensor, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point/Remark: Heat exchanger in & out sensor, Explanation: Indoor unit fan motor malfunction, Main checking Point/Remark: Fan motor and cable, Explanation: More than 2 indoor units cool and heat simultaneously, Main checking Point/Remark: Another indoor unit operation mode, Main checking Point/Remark: Cable connection (Indoor & Outdoor unit), Explanation: The number of indoor unit mismatched, Main checking Point/Remark: Cable connection (another indoor unit & outdoor unit), SW01(outdoor), Explanation: Compressor discharge sensor error(Short/Open), Main checking Point/Remark:  Outdoor unit, Main checking Point/Remark: Outdoor unit (Error code). Check Outdoor Cond. Reinstall the outdoor unitset. Communication error between the Master and Slave wired remote controllers. [Inverter] Current sensor error. [Inverter] IPM over current error. to admin..i also have error code e485 input current sensor error..im a retired hvac tech but have very little exp on mini splits..from what i have read says check power i did that its ok..then said replace pcb which i have on order..could anything else cause it as i dont have tools anymore and samsung tech wont talk to me.i had to order the board through a samsung service company here..could condenser fan motor cause that error?..i found a code for bad motor online e458 but i dont get that just e485. How do I fix an error E654 on my Samsung split AC? In De-ice mode, indoor fan stops and cool air does not come out. Premium Care is free for the first month. Is the filter clogged with dust or dirty? The unit will start in 3 minutes. 2016 2017 2018 2019 2020 2021 Billable/Specific Code Error on float switch (2nd detection). When facing the issue don’t panic and turn to the manual attached here. L'assistenza clienti Samsung mi ha assegnato un centro assistenza di Milano. The table below list the self-diagnostic routines. Is the operation selected among one of Auto / Dry / Turbo / Sleeping? further, the repair man has been to my aircon so many times in an attempt to fix it his comment on the last call was “I feel like part of the family” on the last 2 occasion he found Samsung cant even send the right parts to fix it. To arrange for service, contact Samsung hotline 1-800-10-726-7864 [PLDT Toll Free] or 1-800-8-726-7864 [Globe Toll Free] Have the model number of your air conditioner on hand when you call. Check the option code of the indoor unit. Buonasera, mi sono appena iscritta sperando di poter trovare una soluzione al mio problema. This site uses cookies to personalise your experience, analyse site traffic and keep track of items stored in your shopping basket. Outdoor fan 2 error. Check the resistance between difference phases of the compressor. Check indoor unit floatsensor. Check Outdoor sensor Open / Short. Troubleshooting 4-1 Check-up Window Description No. Smoke is generated from the outdoor unit. Stop. Heating operation blocked. Check again at the state of Cooling / Fan only / Heating. In questo articolo ci soffermiamo sui codici di errore E4 che si riferiscono ai condizionatori Samsung di ultima generazione ma, non solo. Credo si tratti di configurazione dell'unità esterna che, però, negli anni precedenti sin dall'installazione ha sempre funzionato perfettamente. Joseph, Your email address will not be published. Auto restart function is the convenient function where the operation state is memorized in the Memory IC during the blackout and the operation restarts when the power comes back, Samsung Wind Free™ Air Conditioner : Fast Cooling Test, Samsung Split Type Air Conditioner Service Manual PDF, Samsung Multi Air Conditioner Service Manual PDF, DVM S Service Manuals_DVM S Outdoor Unit Service Manual PDF, Samsung official site: https://www.samsung.com/levant/air-conditioners. Is the battery inserted in the wrong way(+, -)? Error on IPM Heat Sink sensor of inverter 1 (Short or Open). Check sensor resistance. Check the connection status between the motor and outdoor unit PCB. ); Trouble: The wind comes out but the heating/cooling is not performed. If you want to operate the air conditioner in the sunlight, cover the outdoor unit using curtains or etc. This website uses cookies to improve your experience while you navigate through the website. The table below give indication about self diagnostic routine. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies.